Stage = 85cm |
We arrived at 10am and set about making a discharge measurement using the float method. The flow was too high to try the wading method with current meter. Using a distance along the bank of 25m, we used branches as floats to measure surface velocity with a stop watch. We used six points across the width of the channel from the bridge. We estimated the mean surface velocity was about 1.5m/s, giving a mean profile velocity of about 1.2m/s (multiply by 0.8). Multiply this by mean depth (0.63m, estimated from current stage and the most recent channel cross-section), and channel width (11.6m), gives total discharge of about 8.75m3/s. Although this estimate is very approximate, it does fit within the bounds of the current stage-rating curve.